Search results for "Duplex ultrasonography"

showing 10 items of 13 documents

Polycystic ovarian syndrome: assessment with color Doppler angiography and three-dimensional ultrasonography.

1999

We conducted a three-dimensional ultrasonographic evaluation of the size and structure of the ovaries of women who had clinical and biochemical findings suggestive of polycystic ovary syndrome. We carried out a comparative color Doppler frequency and color Doppler amplitude study of the vascular patterns of these ovaries. This study involved 65 women of reproductive age with polycystic ovary syndrome and 25 eumenorrheic women who were not taking hormonal contraceptives and who had a body mass index below 25 kg/m2. Compared to controls, women with polycystic ovary syndrome had larger ovaries and thicker stroma, increased impedance in the uterine arteries, increased stromal vascularity with d…

AdultDuplex ultrasonographymedicine.medical_specialtymedia_common.quotation_subjectLuteal phaseVascularitymedicineHumansRadiology Nuclear Medicine and imagingCystObesityProspective StudiesUltrasonography Doppler ColorMenstrual cyclemedia_commonGynecologyRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryOvaryUterusmedicine.diseasePolycystic ovaryAngiographyFemalemedicine.symptombusinessBody mass indexPolycystic Ovary SyndromeJournal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
researchProduct

Transcranial Doppler ultrasound study of the effects of nitrous oxide on cerebral autoregulation during neurosurgical anesthesia: a randomized contro…

2003

Object. Nitrous oxide has an adverse effect on cerebrovascular hemodynamics. Increased intracranial pressure, cerebral blood flow (CBF), cerebral metabolic rate of O2 (CMRO2), and reduced autoregulation indices have been reported, but their magnitudes are still being debated. This study was designed to evaluate the effect of N2O on CBF and autoregulatory indexes during N2O—sevoflurane anesthesia in a prospective randomized controlled series of patients. Methods. Two groups of 20 patients were studied on the basis of the use of N2O in the anesthetic gas mixture. The transient hyperemic response test, which relies on transcranial Doppler ultrasound techniques, was used to assess cerebral hemo…

AdultMaleDuplex ultrasonographyAdolescentUltrasonography Doppler TranscranialNitrous OxideHemodynamicsTranscranial Doppler cerebral autoregulation neurosurgical patientsAnesthesia GeneralCerebral autoregulationNeurosurgical ProceduresmedicineHomeostasisHumansAutoregulationIntracranial pressurebusiness.industrySettore MED/27 - NeurochirurgiaBrainMiddle AgedEchoencephalographyTranscranial DopplerCerebral blood flowAnesthesiaAnestheticFemalebusinessBlood Flow Velocitymedicine.drugJournal of neurosurgery
researchProduct

Color-coded duplex ultrasonography of the origin of the vertebral artery: normal values of flow velocities.

2000

The introduction of color-coded duplex ultrasonography has improved the ease of performing ultrasound investigations of the vertebral arteries. So far, normal values of flow velocities have been reported only for the intertransverse region of the vertebral artery (V2 segments). Atherosclerotic disease at the origin of the vertebral arteries (V0 segment) is frequent and is one of the risk factors for vertebrobasilar ischemic disease. Normal values of flow velocities of the vertebral artery origin are needed to assess pathologic findings, such as vertebral artery origin stenosis or dissection. The aim of this study was to describe the normal flow velocities of vertebral artery origin (V0 segm…

AdultMaleDuplex ultrasonographyVertebral arteryIschemiaDissection (medical)Statistics NonparametricReference Valuesmedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingUltrasonography Doppler ColorVertebral ArteryAgedAged 80 and overUltrasonography Doppler Duplexbusiness.industryUltrasoundAnatomyNomogramMiddle Agedmedicine.diseaseStenosisDuplex (building)FemaleNeurology (clinical)businessBlood Flow VelocityJournal of neuroimaging : official journal of the American Society of Neuroimaging
researchProduct

Evaluation of regional haemodynamics and alterations of vascular wall of the lower limbs in hypertensive subjects

1995

This study was designed to analyse the relationship between arterial hypertension and changes in arterial blood flow and vascular wall damage of the lower limbs in hypertensive patients with various degrees of hypertension. Six hundred and fifty-four hypertensive patients (421 males and 233 females) aged 35 to 70 years and 88 healthy subjects (63 males and 25 females) aged 39 to 60 years were studied. Strain-gauge plethysmography of the lower limbs was used to calculate arterial calf blood flow (RF), arterial calf blood flow after post-ischaemic hyperaemia (PF), basal and minimal vascular resistances (BVR and MVR), time to reach peak flow (tPF), time until 50% reduction of peak flow (tT1/2)…

AdultMaleDuplex ultrasonographymedicine.medical_specialtySettore MED/09 - Medicina InternaHemodynamicsEssential Hypertension Arterial blood flow of the lower limbs medial-intima thickeningHyperaemiaInternal medicinemedicine.arterymedicinePlethysmographHumansKneeAgedUltrasonographyLegbusiness.industryHemodynamicsBlood flowArteriesMiddle AgedSettore MED/11 - Malattie Dell'Apparato CardiovascolarePopliteal arterySurgeryMean blood pressuremedicine.anatomical_structureRegional Blood FlowHypertensionCardiologyFemaleVascular Resistancemedicine.symptomCardiology and Cardiovascular MedicinebusinessTunica IntimaTunica MediaArtery
researchProduct

Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography

1996

The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…

AdultMalemedicine.medical_specialtyDuplex ultrasonographyImage qualitymedicine.medical_treatmentDoppler echocardiographyMitral valve stenosisMitral valveImage Processing Computer-AssistedmedicineHumansMitral Valve StenosisRadiology Nuclear Medicine and imagingCardiac imagingAgedCardiac catheterizationObserver Variationmedicine.diagnostic_testbusiness.industryUltrasoundMiddle Agedmedicine.diseaseEchocardiography Dopplermedicine.anatomical_structureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealThe International Journal of Cardiac Imaging
researchProduct

Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: Definition of a threshold for…

2006

Background Recent reports indicated a correlation between the amount of energy released during endovenous laser treatment (ELT) of the great saphenous vein (GSV) and the success and durability of the procedure. Our objective was to analyze the influence of increased energy dosing on immediate occlusion and recanalization rates after ELT of the GSV. Methods GSVs were treated with either 15 or 30 W of laser power by using a 940-nm diode laser with continuous fiber pullback and tumescent local anesthesia. Patients were followed up prospectively with duplex ultrasonography at day 1 and at 1, 3, 6, and 12 months. Results A total of 114 GSVs were treated with 15 W, and 149 GSVs were treated with …

AdultMalemedicine.medical_specialtyDuplex ultrasonographyTime FactorsAdolescentmedicine.medical_treatmentAngioscopyOcclusionmedicineHumansSaphenous VeinLocal anesthesiaProspective StudiesDosingVeinAgedAged 80 and overUltrasonography Doppler DuplexLaser Coagulationmedicine.diagnostic_testbusiness.industryGreat saphenous veinEndovenous laser treatmentMiddle AgedAngioscopySurgeryTreatment Outcomemedicine.anatomical_structureVenous InsufficiencyChronic DiseaseFemaleSurgeryCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Vascular Surgery
researchProduct

Early detection of embryonic malformations by transvaginal and color Doppler sonography.

1994

A total of 834 women with uneventful pregnancies were followed prospectively until the 15th week of gestation by TVS to screen for early embryonic malformations. Twenty-eight embryonic anomalies were detected in this series (3.3%). The median gestational age at diagnosis was 11 (range, 8 to 15) weeks. Two neural tube defects were missed by early TVS screening. Two suspected abdominal wall defects were not confirmed by repeat mid-second trimester abdominal sonography representing 6.7% of all fetal malformations evident by 24 weeks of gestation. The sensitivity and specificity of TVS screening for fetal malformations in this series were 93.3 and 99.7%, respectively. In addition, the role of T…

Adultmedicine.medical_specialtyDuplex ultrasonographyEarly detectionGestational AgeSensitivity and SpecificityUltrasonography PrenatalCongenital AbnormalitiesAbdominal wallPregnancyPrevalencemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesGynecologyFetusRadiological and Ultrasound Technologybusiness.industryNeural tubeGestational ageEmbryonic stem cellFetal Diseasesmedicine.anatomical_structureGestationFemalebusinessJournal of Ultrasound in Medicine
researchProduct

Reference values of fetal aortic flow velocity waveforms and associated intra-observer reliability in normal pregnancies

2001

Objectives It was the aim of the present study to calculate new Doppler reference ranges for blood flow velocities (Vmax, Vmean, Vmin) and resistance indices (PI, RI) for the fetal descending aorta by automatic waveform analysis. Design Cross-sectional prospective study. Subjects Nine hundred and twenty-six low-risk pregnancies at 18–41 weeks' gestation. Methods Aortic blood flow velocities were derived with pulsed-wave color Doppler. Measurements were carried out at the level of the diaphragm. Reference ranges for the individual measuring parameters were constructed based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square pri…

Aortic archmedicine.medical_specialtyDuplex ultrasonographyAortaRadiological and Ultrasound Technologybusiness.industryObstetrics and GynecologyHemodynamicsGeneral MedicineBlood flowSurgerysymbols.namesakemedicine.anatomical_structureReproductive MedicineInternal medicinemedicine.arteryDescending aortaVascular resistancemedicinesymbolsCardiologyRadiology Nuclear Medicine and imagingbusinessDoppler effectUltrasound in Obstetrics and Gynecology
researchProduct

The Diagnosis and Treatment of Peripheral Arterial Vascular Disease

2016

Background In peripheral arterial occlusive disease (PAOD), arterial stenosis or occlusion impairs perfusion in the territory of the distal portion of the aorta and the iliac and leg arteries. In Germany, the prevalence of PAOD rises with age, reaching 20% among persons over age 70. Methods This guideline was prepared by a collaboration of 22 medical specialty societies and two patient self-help organizations on the basis of pertinent publications that were retrieved by a systematic search in PubMed for articles that appeared from 2008 to April 2014, with a subsequent update to May 2015. Results 294 articles were assessed, including 34 systematic reviews and 98 randomized controlled trials …

Duplex ultrasonographymedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentPhysical examinationClinical Practice GuidelineGeneral MedicineGuideline030204 cardiovascular system & hematologyRevascularizationlaw.inventionSurgery03 medical and health sciences0302 clinical medicineBlood pressureRandomized controlled triallawArterial Occlusive DiseasesMedicine030212 general & internal medicinemedicine.symptombusinessClaudicationDeutsches Ärzteblatt international
researchProduct

Echo-Doppler left ventricular filling abnormalities in patients with rheumatoid arthritis without clinically evident cardiovascular disease

1996

Our investigation aimed at verifying diastolic abnormalities in rheumatoid patients, without clinically evident cardiovascular disease and other confounding complaints, by using pulsed Doppler examination of transmitral blood flow. We selected 40 patients fulfilling revised American Rheumatism Association (ARA) criteria for the diagnosis of rheumatoid arthritis having no symptoms of cardiac disease or clinical findings of other extracardiac diseases. We also studied 40 rheumatoid-matched healthy volunteers as a control group. An echocardiographic examination was carried out on each subject. Left ventricular structural and functional measurements were obtained. Interventricular, septal thick…

MaleDuplex ultrasonographymedicine.medical_specialtySettore MED/09 - Medicina InternaHeart diseaseClinical BiochemistryDiastoleHemodynamicsBlood PressureDoppler echocardiographyBiochemistryAsymptomaticVentricular Function LeftBody Mass IndexArthritis RheumatoidVentricular Dysfunction LeftHeart RateInternal medicineMedicineHumansskin and connective tissue diseasesmedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseSettore MED/45 - Scienze Infermieristiche Generali Cliniche E PediatricheEchocardiography DopplerSurgerySettore MED/16 - Reumatologiamedicine.anatomical_structureVentricleCardiovascular DiseasesRheumatoid arthritiscardiovascular systemCardiologyRegression AnalysisFemalemedicine.symptombusinessDoppler echocardiography left ventricular filling rheumatoid arthritis
researchProduct